肝脏 ›› 2020, Vol. 25 ›› Issue (11): 1175-1177.

• 肝癌 • 上一篇    下一篇

64排MDCT不同碘对比剂浓度对原发性肝癌血流灌注参数的影响及临床意义探索

杨云飞, 谢毅, 焦成文   

  1. 200050 上海市海军特色医学中心肝胆外科
  • 收稿日期:2019-09-05 出版日期:2020-11-30 发布日期:2020-12-22
  • 通讯作者: 焦成文

Effect of different concentrations of iodine contrast agent on the blood perfusion parameters of primary liver cancer measured by 64-row multidetector computed tomography

YANG Yun-fei, XIE Yi, JIAO Cheng-wen   

  1. Department of Hepatobiliary Surgery Shanghai Naval Characteristic Medical Center,Shanghai 200050,China
  • Received:2019-09-05 Online:2020-11-30 Published:2020-12-22
  • Contact: JIAO Cheng-wen

摘要: 目的 初步分析64排MDCT不同碘对比剂浓度对原发性肝癌血流灌注参数的影响,并探讨其临床意义,为原发性肝癌患者影像学结果诊断的进一步精确化及碘对比剂使用的安全性评估提供参考依据。方法 于2017年2月至2018年3月,采用病例抽样的方法抽取上海市海军特色医学中心消化内科及肿瘤科收治的原发性肝癌患者,在征得患者及其家属同意的前提下将所有入选患者随机等额分配至不同碘对比剂浓度组[A组为300 mg I/mL(1.90 mL/kg),B组为380 mg I/mL(1.50 mL/kg)]并行多排螺旋CT检查,同时分析不同碘对比剂浓度组CT检测结果及与肝癌血流参数间的关系。结果 高碘对比剂浓度组的肝实质门脉期CT值、主动脉动脉期CT值、门静脉门脉期CT值、动脉期检出敏感性均显著高于低碘对比剂浓度组,而肝血流量(BF)、肝血容量(BV)、肝动脉灌注量(HAP)均显著低于低碘对比剂浓度组(均有P<0.05)。结论 较高碘对比剂浓度[380 mg I/mL(1.50 mL/kg)]组在64排MDCT检测原发性肝癌过程中有更好的敏感性,同时该组对应的血流灌注各项参数提示患者的肝动脉及门静脉的压力值均相对较低,但二者间的因果关系需进一步验证。

关键词: 64排MDCT, 碘对比剂浓度, 原发性肝癌, 血流灌注参数

Abstract: Objective To analyze the effects of different concentrations of iodine contrast agent on the blood perfusion parameters of primary hepatocellular carcinoma (HCC) measured by 64-row multidetector computed tomography (MDCT),and provide further refined imaging diagnosis of primary liver cancer and references for the safety of iodine contrast agent.Methods Eighty-four patients with HCC were selected by case sampling method.Informed consent was obtained from all patients and their families.Equal numbers of patients were randomly assigned to different concentrations of iodine contrast agent groups,with 300 mg I/mL (1.90 mL/kg) in group A and 380 mg/mL (1.50 mL/kg) in group B.Multi-slice spiral CT (MSCT) was performed in both groups of patients.The association between the CT imaging results as measured by different concentrations of iodine contrast agent and the blood flow dynamic parameters of HCC were analyzed.Results The detection sensitivity of The CT values of hepatic parenchymal portal phase,aortic arterial phase,and portal vein phase and the arterial phase of group A patients were significantly higher,whereas the liver perfusion parameters including hepatic blood flow (BF),blood volume (BV),and hepatic artery perfusion (HAP) were significantly lower than those in group B (both P<0.05).Conclusion when detecting primary liver cancer with 64-row MDCT,using a higher concentration of iodine contrast agent [380 mg I/mL (1.50 mL/kg)] has better sensitivity,corresponding to relative lower values of hepatic artery and portal vein pressure in the blood flow perfusion parameters.The causal relationship warrants further validation.

Key words: 64-row multidetector computed tomography, Concentration of iodine contrast agent, Primary liver cancer, Blood perfusion parameters, Clinical significance